Field # |
|
  |
Field Name |
|
1
|
|
|
ASR NO - Access Service Request Number
|
|
2
|
|
|
ICSC - Interexchange Customer Service Center
|
|
3
|
|
|
TACT - Testing Activity
|
|
4
|
|
|
CCNA - Customer Carrier Name Abbreviation
|
|
5
|
|
|
T-BAN - Test Billing Account Number
|
|
6
|
|
|
IC-MCO - Customer Maintenance Control Office
|
|
7
|
|
|
PON - Purchase Order Number
|
|
8
|
|
|
VER - Version Identification
|
|
9
|
|
|
FETL - Far End Test Equipment Telephone Number
|
|
10
|
|
|
ROTL - Remote Office Test Line
|
|
11
|
|
|
ACTL - Access Customer Terminal Location
|
|
12
|
|
|
CKR - Customer Circuit Reference
|
|
13
|
|
|
ECCKT - Exchange Company Circuit ID
|
|
14
|
|
|
TESTCON - Test Contact
|
|
15
|
|
|
TCON-TEL - Test Contact Telephone Number
|
|
16
|
|
|
TECHAT - Technician At
|
|
17
|
|
|
STREET - Street Address
|
|
18
|
|
|
CITY - City
|
|
19
|
|
|
STATE - State/Province
|
|
20
|
|
|
ZIP CODE - Zip Code
|
|
21
|
|
|
FLOOR - Floor
|
|
22
|
|
|
ROOM - Room
|
|
23
|
|
|
DTSD - Desired Testing Services Date
|
|
24
|
|
|
D/TSENT - Date and Time Sent
|
|
25
|
|
|
ROTY - Test Type
|
|
26
|
|
|
ECAN - Echo Canceller
|
|
27
|
|
|
1004-EML-A - 1004 Hz Test Expected Measured Loss Office A
|
|
28
|
|
|
1004 EML-Z - 1004 Hz Test Expected Measured Loss Office Z
|
|
29
|
|
|
ADT - Attenuation Distortion Test
|
|
30
|
|
|
CMN - C-Message Noise Test
|
|
31
|
|
|
CNT - C-Notched Noise Test
|
|
32
|
|
|
DCC - DC Continuity Test
|
|
33
|
|
|
DPB - Dial Pulse Percent Break Test
|
|
34
|
|
|
ECO - Echo Control Test
|
|
35
|
|
|
EDD - Envelope Distortion Test
|
|
36
|
|
|
FRS - Frequency Shift Test
|
|
37
|
|
|
GAS - Gain and Slope Test
|
|
38
|
|
|
IDT - Intermodulation Distortion Test
|
|
39
|
|
|
IMN - Impulse Noise Test
|
|
40
|
|
|
NVT - Non-Voice Grade Circuit Test
|
|
41
|
|
|
PHJ - Phase Jitter Test
|
|
42
|
|
|
SCN - Signal to C-Notched Noise Radio Test
|
|
43
|
|
|
OTH - Other
|
|
44
|
|
|
GAS-I - Gain Slope Test Interval
|
|
45
|
|
|
1004-I - 1004 Hz test Interval
|
|
46
|
|
|
CMN-I - C-Message Noise Test Interval
|
|
47
|
|
|
CNT-I - C-Notched Noise Test Interval
|
|
48
|
|
|
BAL-I - Balance Test Interval
|
|
49
|
|
|
1004-TTL - 1004 Hz Test Trunk Limits
|
|
50
|
|
|
1004-TML - 1004 Hz Test Trunk Maintenance Limits
|
|
51
|
|
|
1004-TAL - 1004 Hz Test Trunk Action Limits
|
|
52
|
|
|
404-TTL - 404 Hz Test Trunk Limits
|
|
53
|
|
|
404-TML - 404 Hz Test Trunk Maintenance Limits
|
|
54
|
|
|
404-TAL - 404 Hz Test Trunk Action Limits
|
|
55
|
|
|
2804-TTL - 2804 Hz Test Trunk Limits
|
|
56
|
|
|
2804-TML - 2804 Hz Test Trunk Limits
|
|
57
|
|
|
2804-TAL - 2804 Hz Test Trunk Limits
|
|
58
|
|
|
CMN-TTL - C-Message Noise Test Trunk Limit
|
|
59
|
|
|
CMN-TML - C-Message Noise Test Trunk Maintenance Limit
|
|
60
|
|
|
CMN-TAL - C-Message Noise Test Trunk Action Limit
|
|
61
|
|
|
CNT-TTL - C-Notched Noise Test Trunk Limit
|
|
62
|
|
|
CNT-TML - C-Notched Noise Test Trunk Maintenance Limit
|
|
63
|
|
|
CNT-TAL - C-Notched Noise Test Trunk Action Limit
|
|
64
|
|
|
BTL-ERL-A - Balance Trunk Test Limit Echo Return Loss Office A
|
|
65
|
|
|
BML-ERL-A - Balance Trunk Maintenance Limit Echo Return Loss Office A
|
|
66
|
|
|
BAL-ERL-A - Balance Trunk Action Limit Echo Return Loss Office A
|
|
67
|
|
|
BTL-ERL-Z - Balance Trunk Test Limit Echo Return Loss Office Z
|
|
68
|
|
|
BML-ERL-Z - Balance Trunk Maintenance Limit Echo Return Loss Office Z
|
|
69
|
|
|
BAL-ERL-Z - Balance Trunk Action Limit Echo Return Loss Office Z
|
|
70
|
|
|
BTL-SRL-A - Balance Trunk Test Limits Singing Return Loss Office A
|
|
71
|
|
|
BML-SRL-A - Balance Trunk Maintenance Limits Singing Return Loss Office A
|
|
72
|
|
|
BAL-SRL-A - Balance Trunk Action Limits Singing Return Loss Office A
|
|
73
|
|
|
BTL-SRL-Z - Balance Trunk Test Limits Singing Return Loss Office Z
|
|
74
|
|
|
BML-SRL-Z - Balance Trunk Maintenance Limits Singing Return Loss Office Z
|
|
75
|
|
|
BAL-SRL-Z - Balance Trunk Action Limits Singing Return Loss Office Z
|
|
76
|
|
|
REMARKS - Remarks
|